RH CAL, Portable Relative Humidity Calibrator
Model: RH CAL
A microprocessor based, programmable humidity calibration system that is at home in the metrology lab or in the field performing on-site, NIST traceable humidity calibrations.
RH CAL is entirely self-sufficient. It does not need compressed air or a water connection to operate, which allows this system to be truly portable.
- Measurement Ranges:
Relative humidity: 5 to 95%
Temperature: 10°C to 50°C
Dew/Frost Point: -40°C to 60°C with D2 sensor
- Accuracy:
Relative humidity: ±0.5%
Temperature: ±0.1°C
Dew/Frost Point: ±0.2°C nominal
Please refer to product’s datasheet (PDF)
TH110 – Kimo Humidity and Temperature Sensor
Kimo’s TH 110 measured humidity and temperature from 5 to 95% RH and from 0 to 50°C.
- Measuring range from 5 to 95% RH and from 0 to 50°C (ambient model) or from -20 to +80°C (duct or remote model)
- 0-10 V output or 4-20 mA output
- With or without 10-digits LCD display
- Housing with simplified mounting system
- Software or DIP switch configuration
- Quick and easy mounting with the 1/4 turn system with wall-mount plate
Please download the datasheet here.
TH210 – Kimo Humidity and Temperature Sensor
Kimo’s TH 210-R measures humidity and temperature including 0 to 100 % RH and -20 to +80°C (ambient model), -20 to +80°C (pc remote probe), and -40 to +180°C (stainless steel remote probe).
- Stainless steel or polycarbonate probe
- With or without 2-line 19-digits LCD display
- 0-5/10 V or 0/4-20 mA outputs
- Trend indicator
- Two relays
- Quick and easy mounting with the 1/4 turn system with wall-mount plate
Please download the datasheet here. (pdf)
C310 – Kimo Multifunction Sensor
Kimo’s C 310 is a multifunction sensor with interchangeable probes. It can display and measure four parameters simultaneously.
FEATURES
- Two inputs for probes
- Four visual and audible alarms
- Two analogue outputs 0-5/10 V or 0/4-20 mA
- Four RCR relays (option)
- Ethernet communication (option) and RS485 MODBUS (option)
- Adjustment certificate
Please download the datasheet here.
HM70 – Handheld Humidity and Temperature Meter
Vaisala HUMICAP® HM70 Handheld is designed for demanding humidity measurement in spot-checking applications. It is also ideal for field checking and calibration of Vaisala’s fixed humidity instruments.
The HM70 includes an MI70 indicator and an optional probe depending on the application.
- HMP75 with standard plastic grid
- HMP75B (chemical purge and sensor preheating)
- HMP76 with standard sintered bronze filter
- HMP76B (chemical purge and sensor preheating)
- HMP77 with standard plastic grid and stainless steel netting
- HMP77B (chemical purge and sensor preheating)
Please download the datasheet here. (pdf)
BG-HT-08P, Blue Gizmo Digital Thermo-Hygrometer with External Probe
FUNCTIONS
- To monitor outdoor temperature and indoor climate
- Indoor temperature and humidity
- To monitor outdoor temperature and indoor climate
- Indoor temperature and humidity
- Outdoor temperature via cable
- For the monitoring of freezer / aquarium
- Max / Min function
- Wall mounting and standing purposes
SPECIFICATIONS
- Temperature Range
Outdoor (Cable Sensor) -40 …+70°C
Indoor 0 …+50°C - Temperature Accuracy ±1.0°C at 0 …+40°C otherwise ±1.5°C
- Humidity Range 20 … 99% RH
- Humidity Accuracy ±5% at 30 …80% RH otherwise ±7%
- Sensor Cable Length 200 cm
Please download the datasheet here. (pdf)
TS 325 – Taishio High Accuracy Temperature Head Transmitter HART®
FEATURES
• Universal Input (RTD/TC/mV/Ω)
• Universal setting with HART®-protocol
• High accuracy in total ambient temperature range: 0.02% of span for Pt100 sensor , 0.1% of span for TC sensor
• Programmable via PC-Software
• 2-wire technology, 4 to 20mA analogue output
• Galvanic isolation (2000V AC)
• Internal temperature sensor for active temperature compensation (for TC sensor)
• Fault signal on sensor break or short circuit, presetable to NAMUR NE 43
Please download the datasheet here. (pdf)
TaishioTS 323 – High Accuracy Temperature Head Transmitter
FEATURES
• Programmable temperature head transmitter
• Galvanic Isolated
• Input: RTD (PT100, PT500, PT1000
• Thermocouples B, E, J, K, N, R, S,T
• Factory Preset (PT100, 3-wire, 0 to 100°C)
• Output Signal: 4 to 20mA, 2-wire
Please download the datasheet here. (pdf)
TS307 – Taishio Outdoor Temperature and Humidity Transmitter with Shield
FEATURES
• High accuracy and long term stability
• capable of temperature compensation and linear adjustment
SPECIFICATIONS
• Temp range : 0 to 80°C
• Output 4 to 20mA
• Humidity range : 0 to 100% RH
• Dew point : -40 to 60°C
• Signal connection : 3 wires
Please download the datasheet here. (pdf)
Taishio Din Rail Transmitter – Thermocouple, TS 213TC
• K,J,N,E,T,R,S Thermocouples Plus mV
• Simple push button configuration
• Advanced user config for access to 7 preset temperature ranges
• User push button trim
• Programmable burn out
• Galvanic isolation
OUTPUT
• Output Type 2 wire (4 to 20) mA current loop
• Output Range 4.0 mA to 20.0 mA
• Output connection Screw Terminal
• Maximum output 21.5 mA(in high burnout condition)
• Minimum output 3.8 mA(in low burnout condition)
• Accuracy (mA output / 2000) or 5 uA(Which ever is the greater)
• Max output load [(Vsupply -10) / 20) K Ohms (Example 700 ohms @ 24V)
TS 203TC – Taishio Thermocouple Transmitter
Input
- K (-200 to 1370°C)
- J (-100 to 1200°C)
- E ( -200 to 1000°C)
- N (-180 to 1300°C)
- T (-200 to 400°C)
- R (-10 to 1760°C)
- S (-10 to 1760°C)
- Accuracy : ±0.1%fs ±0.5°C
- Input mV ( -10 to 70mV)
- Accuracy ±0.2%fs
- Isolation Tested to 250vdc
- Sensor Burnout Either up or down scale output
- Cold Junction Range (-40 to 85°C) ;Accuracy ±0.5°C
- Stability Span 0.05°C/°C
- Output Range : 2 Wires (4 -20mA) current loop
- Output Connection Screw Terminal
Please download the datasheet here. (pdf)
TS 203P – Taishio PT100 Temperature Transmitter
The transmitter is allow cost “smart” in head transmitter that accepts PT100 temperature sensors and converts sensor output over a configured range to a standard industrial (4-20)mA transmission signal.
SPECIFICATIONS @ 20ºC
- Input PT100 100R @ 2 or 3 Wire
- Range : (-200 to +850) ºC (18 to 390)Ω
- Min. span : 25ºC
- Linearisation : BS EN 60751(IEC 751) standard /
- Measurement Accuracy : 0.2ºC ± 0.05% of Reading
- Excitation current : <200 μA
- Max lead Resistance : 20 Ohms per leg
- Output : 2 wire (4 to 20) mA current loop
- Range : (4.0 to 20.0) mA
- Max output : 2 wire (4 to 20) mA current loop