TS307 – Taishio Outdoor Temperature and Humidity Transmitter with Shield
FEATURES
• High accuracy and long term stability
• capable of temperature compensation and linear adjustment
SPECIFICATIONS
• Temp range : 0 to 80°C
• Output 4 to 20mA
• Humidity range : 0 to 100% RH
• Dew point : -40 to 60°C
• Signal connection : 3 wires
Please download the datasheet here. (pdf)
Taishio Din Rail Transmitter – Thermocouple, TS 213TC
• K,J,N,E,T,R,S Thermocouples Plus mV
• Simple push button configuration
• Advanced user config for access to 7 preset temperature ranges
• User push button trim
• Programmable burn out
• Galvanic isolation
OUTPUT
• Output Type 2 wire (4 to 20) mA current loop
• Output Range 4.0 mA to 20.0 mA
• Output connection Screw Terminal
• Maximum output 21.5 mA(in high burnout condition)
• Minimum output 3.8 mA(in low burnout condition)
• Accuracy (mA output / 2000) or 5 uA(Which ever is the greater)
• Max output load [(Vsupply -10) / 20) K Ohms (Example 700 ohms @ 24V)
TS 203TC – Taishio Thermocouple Transmitter
Input
- K (-200 to 1370°C)
- J (-100 to 1200°C)
- E ( -200 to 1000°C)
- N (-180 to 1300°C)
- T (-200 to 400°C)
- R (-10 to 1760°C)
- S (-10 to 1760°C)
- Accuracy : ±0.1%fs ±0.5°C
- Input mV ( -10 to 70mV)
- Accuracy ±0.2%fs
- Isolation Tested to 250vdc
- Sensor Burnout Either up or down scale output
- Cold Junction Range (-40 to 85°C) ;Accuracy ±0.5°C
- Stability Span 0.05°C/°C
- Output Range : 2 Wires (4 -20mA) current loop
- Output Connection Screw Terminal
Please download the datasheet here. (pdf)
TS 203P – Taishio PT100 Temperature Transmitter
The transmitter is allow cost “smart” in head transmitter that accepts PT100 temperature sensors and converts sensor output over a configured range to a standard industrial (4-20)mA transmission signal.
SPECIFICATIONS @ 20ºC
- Input PT100 100R @ 2 or 3 Wire
- Range : (-200 to +850) ºC (18 to 390)Ω
- Min. span : 25ºC
- Linearisation : BS EN 60751(IEC 751) standard /
- Measurement Accuracy : 0.2ºC ± 0.05% of Reading
- Excitation current : <200 μA
- Max lead Resistance : 20 Ohms per leg
- Output : 2 wire (4 to 20) mA current loop
- Range : (4.0 to 20.0) mA
- Max output : 2 wire (4 to 20) mA current loop
Please download the datasheet here. (pdf)
TS13 / TS14 – Taishio Temperature & Humidity Transmitter Indoor / Duct
SPECIFICATIONS
- Output:4 … 20 mA / 2-wire
- Input type : Capacitive humidity sensor & Pt1000 Ω
- Accuracy(at 25°C):±0.3°C+0.002°C x tactual;±3%RH(20 … 80%)
- Measuring range:0 … 50°C;0 … 100%RH
- IP rating: IP54 (Sensor: IP20)
Please download the datasheet here. (pdf)
BG-HT09, Blue Gizmo Digital Thermo-Hygrometer
SPECIFICATIONS
• Measuring Temperature Range : – 10°C to +50°C
• Measuring Humidity Range : 20% to 99% RH
• Accuracy:
Temperature : 0°C to +60°C, (+ 1.0°C)
Humidity: 30% to 75%, + 5% otherwise + 8% RH
BG-TM100, Blue Gizmo Digital Freezer-Fridge Thermometer
SPECIFICATIONS
- Measuring Temperature Range: – 30°C to +50°C
- Resolution: ±0.1°C
- Accuracy: ±0.8°C at -20°C to +10°C otherwise ±1°C
- Operating Temperature: – 30°C to +50°C
Please download the datasheet here. (pdf)
BG-GA-4, Blue Gizmo Digital Oven Thermometer
SPECIFICATIONS
- Measuring Range: 50 ~ 300°C
- Colour-coded temperature guide for fast reading
Please download the datasheet here. (pdf)